Voltify logo with UL Listed certification
Galvanized Flexible Steel Conduit (1)

Flexible Conduit and Fittings

Galvanized Flexible Steel Conduit

Material
Steel
Finish
Galvanised
Color
Shine
Size
3/8″ to 6″
Usage
Highly flexible with protection against ingress of solid particles and most common liquids

Product Details

Flexible Conduit and Fittings

US Type Flexible Steel Conduit

Material
Steel
Finish
Galvanized
Coil Length
100/50/30/15/10M
Size
3/8″ to 4″
Usage
Designed for proofing against water,oil and dust and for assuring high tensile strength and twist resistance.Its smooth inner surface makes wiring pulling easy.
Voltify logo with UL Listed certification
US Type Flexible Steel Conduit (2)

Product Details

* Application: Widely used for general electrical wiring where flexibility and mechanical protection are required.

* Construction: This standard duty flexible conduit is square locked type and helically wound from electro-galvanized steel strip.

* Trade size:

3/8″

Galvanized

 1/2″Galvanized

3/4″

Galvanized

1″

Galvanized

1-1/4″

Galvanized

1-1/2″

Galvanized

2″

Galvanized

2-1/2″

Galvanized

3″

Galvanized

4″

Galvanized

Voltify logo with UL Listed certification
PVC Coated Flexible Conduit,Grey (3)
Flexible Conduit and Fittings

PVC Coated Flexible Conduit,Grey

Material
Galvanized Steel+PVC Jacket
Coil Length
100/50/30/15/10M
Color
Black/Grey
Size
3/8″ to 6″
Usage
Designed for proofing against water,oil and dust and for assuring high tensile strength and twist resistance.Its smooth inner surface makes wiring pulling easy.

Product Details

3/8″
Galvanized with PVC Coated
1/2″ Galvanized with PVC Coated
3/4″
Galvanized with PVC Coated
1″
Galvanized with PVC Coated
1-1/4″
Galvanized with PVC Coated
1-1/2″
Galvanized with PVC Coated
2″
Galvanized with PVC Coated
2-1/2″
Galvanized with PVC Coated
3″
Galvanized with PVC Coated
4″
Galvanized with PVC Coated
5″ Galvanized with PVC Coated
6″ Galvanized with PVC Coated
Flexible Conduit and Fittings

Liquid Tight Flexible Conduit,Grey Color

Material
Galvanized Steel+PVC Jacket
Finish
with Filler of Cord
Type
Insulated
Coil Length
100/50/30/15/10M
Color
Black/Grey
Size
3/8″ to 4″
Usage
Designed for proofing against water,oil and dust and for assuring high tensile strength and twist resistance.Its smooth inner surface makes wiring pulling easy.
Voltify logo with UL Listed certification
Liquid Tight Flexible Conduit,Grey Color (4)

Product Details

For use in outdoor locations

Sunlight resistant PVC jacket

Approved for use in temperatures from -10 to +60 C

Steel zinc plated

IP68

Trade size:

3/8″
Heavy PVC coated
1/2″  Heavy PVC coated
3/4″
Heavy PVC coated
1″
Heavy PVC coated
1-1/4″
Heavy PVC coated
1-1/2″
Heavy PVC coated
2″
Heavy PVC coated
2-1/2″
Heavy PVC coated
3″
Heavy PVC coated
4″
Heavy PVC coated
Voltify logo with UL Listed certification
Straight Squeeze BX Connector (5)
Flexible Conduit and Fittings

Straight Squeeze BX Connector

Material
Zinc Die Cast
Finish
Galvanized
Type
Un-insulated
Standard
UL 514 B
Thread
NPT
Size
3/8″ to 4″
Usage
Use to terminate regular wall steel flexible metal conduit to a knock-out in a dry location box or

Product Details

Straight-Squeeze-BX-Connector-product-detail-5
Flexible Conduit and Fittings

90 degree Squeeze Connector

Material
Zinc Die Cast
Type
Non-Insulated
Standard
UL  Standard
Thread
NPT
Size
1/2″ to 4″
Usage

Using for connectoring Galvanized flexible conduit and steel box

Voltify logo with UL Listed certification
90 degree Squeeze Connector (6)

Product Details

90 degree Squeeze Connector (product detail) (6)
Voltify logo with UL Listed certification
BX Straight Connector (7)
Flexible Conduit and Fittings

BX Straight Connector

Material
Zinc Die Cast
Finish
Galvanized
Type
Uni-insulated
Thread
NPT
Size
1/2″ 3/4″ 1″
Usage
Use to terminate regular wall steel flexible metal conduit to a knock-out in a dry location box or enclosure

 

Product Details

Trade size:   

1/2″       Zinc die cast  
3/4″        Zinc die cast        
1″        Zinc die cast
Flexible Conduit and Fittings

Flex Conduit Connector

Material
Zinc Die Cast
Finish
Galvanized
Type
Uni-insulated
Thread
NPT
Size
1/2″ 3/4″ 1″
Usage
Use to terminate regular wall steel flexible metal conduit to a knock-out in a dry location box or enclosure

 

Voltify logo with UL Listed certification
Flex Conduit Connector (8)

Product Details

Trade size:   

1/2″       Zinc die cast  
3/4″        Zinc die cast        
1″        Zinc die cast
Voltify logo with UL Listed certification
Straight Liquid Tight Connector (9)
Flexible Conduit and Fittings

Straight Liquid Tight Connector

Material
Zinc Die Cast
Finish
Galvanized
Type
Insulated
Thread
NPT
Size
3/8″ to 6″
Usage
Fit the most common sizes of metallic liquid tight conduit. Supplied with locknut and plastic sealing ring.

Product Details

Straight Liquid Tight Connector (product detail) (9)
Flexible Conduit and Fittings

Liquid Tight 90°Connector,Insulated

Material
  Zinc Die Cast
Type
  Insulated
Size
  3/8”to 4″
Usage

  Fit the most common sizes of metallic liquid 

  tight conduit.Supplied with locknut and plastic 

  sealing ring.

Voltify logo with UL Listed certification
Liquid Tight 90°Connector,Insulated (10)

Product Details

Liquid Tight 90°Connector,Insulated (product detail) (10)
Voltify logo with UL Listed certification
Liquid Tight Connector Straight,Malleable (11)
Flexible Conduit and Fittings

Liquid Tight  Connector
Straight, Malleable

Material
  Malleable Iron
Finished
  Galvanized
Type
  Insulated / Un-insulated
Standard
  UL 514B
Thread
  NPT
Size
  3/8″ to 2″
Usage 

  Use to connect liquid-tight conduit to a steel

  outlet box or other metal enclosure or hub

Product Details

Cat.No.SizeMaterials
SLT-038M3/8″Malleable Iron
SLT-050M1/2″Malleable Iron
SLT-075M3/4″Malleable Iron
SLT-100M1″Malleable Iron
SLT-125M1-1/4″Malleable Iron
SLT-150M1-1/2″Malleable Iron
SLT-200M2″Malleable Iron
Flexible Conduit and Fittings

45° Liquid Tight Connector,Malleable

Material
 Malleale Iron
Finish
 Galvanized
Type
 Insulated / Un-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ to 2″
Usage

 Use to connect liquid-tight conduit to a steel 

 outlet box or other metal enclosure or hub

Voltify logo with UL Listed certification
45° Liquid Tight Connector,Malleable (12)

Product Details

Cat.No.SizeMaterials
ALT-038453/8″Malleable Iron
ALT-050451/2″Malleable Iron
ALT-075453/4″Malleable Iron
ALT-100451″Malleable Iron
ALT-125451-1/4″Malleable Iron
ALT-150451-1/2″Malleable Iron
ALT-200452″Malleable Iron
Voltify logo with UL Listed certification
90°Liquid Tight Connector,Malleable (13)
Flexible Conduit and Fittings

90°Liquid Tight Connector,Malleable

Material
 Malleale Iron
Finish
 Galvanized
Type
 Insulated / Un-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ to 2″
Usage

 Use to connect liquid-tight conduit to a steel 

 outlet box or other metal enclosure or hub

Product Details

Cat.No.SizeMaterials
ALT-038903/8″Malleable Iron
ALT-050901/2″Malleable Iron
ALT-075903/4″Malleable Iron
ALT-100901″Malleable Iron
ALT-125901-1/4″Malleable Iron
ALT-150901-1/2″Malleable Iron
ALT-200902″Malleable Iron
Flexible Conduit and Fittings

Grounding Liquid Tight Connector Straight,Malleable

Material
 Malleale Iron
Finish
 Galvanized
Type
 Insulated / Un-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ to 2″
Usage

 Use to connect liquid-tight conduit to a steel 

 outlet box or other metal enclosure or hub

Voltify logo with UL Listed certification
Grounding Liquid Tight Connector Straight,Malleable (14)

Product Details

Cat.No.SizeMaterials
GSLT-0383/8″Malleable Iron
GSLT-0501/2″Malleable Iron
GSLT-0753/4″Malleable Iron
GSLT-1001″Malleable Iron
GSLT-1251-1/4″Malleable Iron
GSLT-1501-1/2″Malleable Iron
GSLT-2002″Malleable Iron
Voltify logo with UL Listed certification
45° Grounding Liquid Tight Connector,Malleable (15)
Flexible Conduit and Fittings

45° Grounding Liquid Tight Connector,Malleable

Material
 Malleale Iron
Finish
 Galvanized
Type
 Insulated / Un-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ to 2″
Usage

 Use to connect liquid-tight conduit to a steel 

 outlet box or other metal enclosure or hub

Product Details

Cat.No.SizeMaterials
GALT-038453/8″Malleable Iron
GALT-050451/2″Malleable Iron
GALT-075453/4″Malleable Iron
GALT-100451″Malleable Iron
GALT-125451-1/4″Malleable Iron
GALT-150451-1/2″Malleable Iron
GALT-200452″Malleable Iron
Flexible Conduit and Fittings

90° Grounding Liquid Tight Connector,Malleable

Material
 Malleale Iron
Finish
 Galvanized
Type
 Insulated / Un-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ to 2″
Usage

 Use to connect liquid-tight conduit to a steel 

 outlet box or other metal enclosure or hub

Voltify logo with UL Listed certification
90° Grounding Liquid Tight Connector,Malleable (16)

Product Details

Cat.No.SizeMaterials
GALT-038903/8″Malleable Iron
GALT-050901/2″Malleable Iron
GALT-075903/4″Malleable Iron
GALT-100901″Malleable Iron
GALT-125901-1/4″Malleable Iron
GALT-150901-1/2″Malleable Iron
GALT-200902″Malleable Iron
Voltify logo with UL Listed certification
DPJ Type Flex to Box Male Connector (17)
Flexible Conduit and Fittings

DPJ Type Flex to Box Male Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 G / NPT / PG / Metric
Size
 3/8″ to 6″
Usage

 Use to connect liquid-tight conduit or Flex Pipe 

  to a steel outlet box or other metal enclosure or

 hub

Flexible Conduit and Fittings

DPN Type Flex to Threaded Conduit Adaptor

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 G / NPT / PG / Metric
Size
 1/4″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe
 to a Threaded Pipe
Voltify logo with UL Listed certification
DPN Type Flex to Threaded Conduit Adaptor (18)
Voltify logo with UL Listed certification
DKJ Type Flex to Steel Pipe Adaptor (19)
Flexible Conduit and Fittings

DKJ Type Flex to Steel Pipe Adaptor

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 no threaded,fit with EMT,IMC or Rigid Pipe
Size
 3/8″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe 
 to Steel Pipe
Flexible Conduit and Fittings

DGJ Type Flex to Steel Pipe Compression Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 No threaded
Size
 3/8″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe 
  to steel Pipe

 

Voltify logo with UL Listed certification
DGJ Type Flex to Steel Pipe Compression Connector (20)
Voltify logo with UL Listed certification
DGJ Type Flex to Flex Compression Connector (21)
Flexible Conduit and Fittings

DGJ Type Flex to Flex Compression Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 No threaded
Size
 3/8″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe 
 to Flex Pipe
Flexible Conduit and Fittings

DNJ Type Flex to Box 45° Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 G / NPT / PG / Metric
Size
 3/8″ to 6″
Usage

 Use to connect liquid-tight conduit or Flex Pipe

 to a steel outlet box or other metal enclosure or 

 hub

Voltify logo with UL Listed certification
DNJ Type Flex to Box 45° Connector (22)
Voltify logo with UL Listed certification
DWJ Type Flex to Box 90° Connector (23)
Flexible Conduit and Fittings

DWJ Type Flex to Box 90° Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Hex Nut
Thread
 G / NPT / PG / Metric
Size
 3/8″ to 6″
Usage

 Use to connect liquid-tight conduit or Flex Pipe

 to a steel outlet box or other metal enclosure or hub

Flexible Conduit and Fittings

DPJD Type Flex to Box Male Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Quincunx Nut
Thread
 G / NPT / PG / Metric
Size
 3/8″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe to a 
 steel outlet box or other metal enclosure or hub
Voltify logo with UL Listed certification
DPJD Type Flex to Box Male Connector (24)
Voltify logo with UL Listed certification
DPND Type Flex to Threaded Conduit Adaptor (25)
Flexible Conduit and Fittings

DPND Type Flex to Threaded Conduit Adaptor

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Quincunx Nut
Thread
 G / NPT / PG / Metric
Size
 1/4″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe to a   Threaded Pipe
Flexible Conduit and Fittings

DKJD Type Flex to Steel Pipe Adaptor

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Quincunx Nut
Thread
 No threaded,fit with EMT,IMC or Rigid Pipe
Size
 3/8″ to 6″
Usage
 Use to connect liquid-tight conduit or Flex Pipe to         Steel Pipe
Voltify logo with UL Listed certification
DKJD Type Flex to Steel Pipe Adaptor (26)
Voltify logo with UL Listed certification
DWJD Type Flex to Box 90° Connector (27)
Flexible Conduit and Fittings

DWJD Type Flex to Box 90° Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Insulated and Quincunx Nut
Thread
 G / NPT / PG / Metric
Size
 3/8″ to 6″
Usage

 Use to connect liquid-tight conduit or Flex Pipe 

 to a steel outlet box or other metal enclosure or

 hub

Flexible Conduit and Fittings

Metal Ferrule

Material
 Steel 
Finish
Galvanized
Size
1/4″ to 6″
Usage

General industrial and commerical 

electrical wiring protection

Voltify logo with UL Listed certification
Metal Ferrule (28)
Voltify logo with UL Listed certification
Metal Ferrule Screw type (29)
Flexible Conduit and Fittings

Metal Ferrule Screw type

Material
 Steel 
Finish
Galvanized
Size
1/4″ to 6″
Usage

General industrial and commerical 

electrical wiring protection

Flexible Conduit and Fittings

Screw in Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Non-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ 1/2″ 3/4″ 1″
Usage

 Use to terminate flexible metal conduit to a 

 knock-out or enclosure where minimum 

 spacing is desired between the conduits

Voltify logo with UL Listed certification
Screw in Connector (30)

Product Details

Trade size:  Materials
   3/8″  Zinc die cast
    1/2″    Zinc die cast
    3/4″    Zinc die cast
    1″    Zinc die cast
Voltify logo with UL Listed certification
Screw in Connector (30)
Flexible Conduit and Fittings

Screw in Connector,Aluminum

Material
 Aluminum
Type
 Non-insulated
Standard
 UL 514B
Thread
 NPT
Size
 3/8″ 1/2″ 3/4″ 1″
Usage

 Use to terminate flexible metal conduit to a 

 knock-out or enclosure where minimum s

 pacing is desired between the conduits

Product Details

Trade  size:  Materials
    3/8″  Aluminum
    1/2″    Aluminum
    3/4″    Aluminum
    1″    Aluminum
Flexible Conduit and Fittings

Screw-in Coupling

Material
  Zinc Die Cast
Finish
 Galvanized
Type
 Non-insulated
Standard
 UL 514B
Thread
 NPT
Size
 1/2″ 3/4″ 1″
Usage

Use to terminate two flexible metal conduit

Voltify logo with UL Listed certification
Screw-in Coupling (31)

Product Details

Trade   size:  Materials
    1/2″    Zinc die cast
    3/4″    Zinc die cast
    1″    Zinc die cast
Voltify logo with UL Listed certification
NM Cable Romex Connector (32)
Flexible Conduit and Fittings

NM Cable Romex Connector

Material
 Zinc Die Cast
Finish
 Galvanized
Type
 Non-insulated
Standard
 UL 514B
Thread
 NPT
Size
 1/2″ 3/4″ 1″
Usage

Use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure

Product Details

Trade   size:      Material
  3/8″  Zinc die cast
    1/2″    Zinc die cast
    3/4″    Zinc die cast
    1″    Zinc die cast
Scroll to Top